CertiFiber Pro Optical Loss Test Set
Installing a high performance fiber optic cabling system starts with systems design and ends with systems
acceptance. Certifying cabling to industry performance standards is a core element of the process. The
faster it goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process
down - setting the tester up incorrectly, testing to the wrong limits, waiting for lead technicians to analyze
or troubleshoot failures, misinterpretation of results, and test reports that customers can’t understand.
The CertiFiber Pro Optical Loss Test Set (OLTS) helps cabling professionals accomplish more than ever. It’s
all about accurate, error-free certification, making jobs easier to manage and certifying fiber optic cabling
to industry standards, faster. CertiFiber Pro OLTS complies with all applicable cabling standards, which
call out the new Encircled Flux launch condition requirements for optical sources. It’s not just for the
expert technicians and Project Managers. Individuals of various skill levels can improve the set-up,
operation, test reporting, and simultaneously manage diverse projects.

Unique features: - Taptive user interface puts advanced data analysis and easy set-up and
- Versiv enables users to accomplish more than ever with a cable tester, operation at the fingertips of technicians of all skill levels

accelerating every step of the testing process - LinkWare management software provides unmatched analysis of test results
- ProjX management system eases tasks from initial set-up of a job to system and professional test reports

acceptance. It eliminates redundant steps, and ensures that all tests are - Encircled Flux compliant optical launch conditions required by ANSI/TIA
completed correctly the first time, and every time and ISO/IEC standards for testing multimode fiber
Standards:
- Allows combined OLTS Tier 1 (basic), OTDR Tier 2 (extended) certification,
end-face inspection and reporting when paired with OptiFiber™ Pro OTDR
- Set reference wizard verifies test reference cords (TRCs) per ISO/IEC
14763-3 and eliminates negative loss errors

Power Meter Specifications Loss/Length Specifications (cont)

Input Connector Interchangeable connector adapter Launch Condition1,2 Encircled Flux compliant to TIA-526-14-B, ISO/
IEC 14763-3 and IEC 61280-4-1
Detector Type (LC standard, SC, ST and FC optional) Fiber Types Tested 50/125 µm or singlemode
Wavelengths InGaAs 62.5/125 µm
Power Measurement Range 850, 1300, 1310, 1550nm Source Type & Wavelengths LED source 850 ± 30 Fabry-Perot laser
0 dBm to -65 dBm (850 nm) 0 dBm to
-70 dBm (all other wavelengths) nm 1300 ± 20 nm diode 1310 ± 20 nm
Power Measurement Uncertainty1,2 < +/- 5% +/- 32 pW 1550 ± 30 nm
Measurement Linearity3 < ± 0.1 dB Max. Length Measurement 12 km 130 km
Re-calibration Period 1 year Length Measurement ± 1.5 m plus ± 1 % of length
1. +/- 100 pW at 850 nm
2. Under the following conditions: Power level 100 μW (-10 dBm), continuous Accuracy
wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA Output Power (Nominal) ≥ -24 dBm with EF-TRC ≥ -4 dBm
= 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm. Ambient temperature Output Power Stability3 ± 0.05 dB over 8 hours ± 0.1 dB over 8 hours
± 0.03 dB over 15 ± 0.08 dB over 15
23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm- minutes minutes
up. Traceable to NIST. 1. At the output of the EF-TRC
3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 2. Variations between EF measurement equipment may occur but EF
1°C. After a 5 minute warm-up. compliance can be expected with a 95% confidence factor
3. Relative to power level after 15 minute warm up at constant temperature

Loss/Length Specifications Source Wavelengths 850, 1300, 1310 nm, 1550 nm
Power Measurement Range 0 dBm to -65 dBm (850 nm) 0
Specification CertiFiber Pro Multimode CertiFiber Pro Power Measurement Uncertainty1, 2 dBm to -70 dBm
Modules Singlemode Modules < +/- 5% +/- 32 pW
Testing Speeds (excludes Smart Remote mode: < 3 seconds (2
referencing times) wavelengths, one direction, auto wavelength
detection)
Far End Source mode: ≤ 2 seconds (2 Measurement Linearity3 < ± 0.1 dB
wavelengths, one direction auto wavelength Re-calibration Period 1 year
1. +/- 100 pW at 850 nm
detection) 2. Under the following conditions: Power level 100 μW (-10 dBm), continuous
Loopback mode: ≤ 2 seconds (2 wavelengths, wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA
one direction auto wavelength detection)
Input/Output Connectors Interchangeable connector adapter = 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm. Ambient temperature
23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute
(LC standard, SC, ST and FC optional) warm-up. Traceable to NIST.

CFP-100-M 1 Versiv Mainframe & Remote, (2) CertiFiber Pro Multimode OLTS Modules, SC/LC EF-compliant MM TRC Kit 50 um, TRC Carry- $8350.00
ing Case, (2) LC/LC Adaptors, (2) Hand Straps, (2) Shoulder Straps, Carry Case, USB Interface Cable, LinkWare Software CD, User
Manual CD, (2) AC Chargers, Statement of Calibration and Getting Started Guide
CFP-100-S 1 Versiv Mainframe & Remote, (2) CertiFiber Pro Singlemode OLTS modules, SC/LC SM TRC Kit, TRC Carrying Case, (2) LC/LC Adap- $10450.00
tors, (2) HandStraps, (2) Shoulder Straps, Carry Case, USB interface cable, LinkWare Software CD, User Manual CD, (2) AC Chargers,
Statement of Calibration and Getting Started Guide
CFP-100-Q 1 Versiv Mainframe & Remote, (2) CertiFiber Pro Quad OLTS modules, SC/LC EF-compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, $13150.00
TRC Carrying Case, (2) LC/LC Simplex Adaptors, (2) HandStraps, (2) Shoulder Straps, Carry Case, USB Interface Cable, LinkWare
Software CD, User Manual CD, (2) AC Chargers, Statement of Calibration and Getting Started Guide

Major Credit Cards Accepted 1.800.543.4333 • Fax 203.325.2198 • www.datacomtools.com 5
   1   2   3   4   5   6   7   8   9   10