Optical Light Sources

Optical Light Source Dual Laser Light Source with Wave ID
The OLS1 is a cost-effective, rugged, handheld LED light source for performing The OLS2-Dual is a handheld, rugged laser
insertion loss measurements on fiber optic links when used with an optical source for performing insertion loss measure-
power meter. The LED output is stabilized to ensure accurate test results per ments on SM fiber optic links when used with a
current TIA/EIA requirements. power meter.
The OLS2-Dual features 1310nm & 1550nm
The OLS1 is easy to operate with only a [Wavelength/Power] switch, which LASER output from one output port & offers sev-
selects optical wavelengths or disables unit. [Active Output], [Battery], and eral modes of operation. When transmitting with
[External Power] indicators identify the currently enabled output port, battery Wave ID, the OLS2-Dual supports transmitting
charge status, & external power presence. The OLS1 operates over 60 hours pairs of wavelengths in an alternating pattern.
from a typical 9V alkaline battery.

OLS 1-1C Optical Light Source 660nm-850nm (ST) $375.00 OLS2-DUAL Dual Laser Light Source with Wave ID $1535.00
OLS1-2C Optical Light Source 850nm-1300nm (ST) $655.00
OLS1-DUAL Optical Light Source 850nm-1300nm (SC/ST) $745.30

Triple Wavelength Laser Sources Laser Light Source with Wave ID
The OLS7 from AFL Telecommunications are laser sources designed for per- The OLS4 from AFL Telecommunication is a
forming insertion loss measurements on SM fiber optic links when used with an handheld, two-port LED & LASER light source
optical power meter. When paired with an optical fiber identifier, both models designed for performing insertion loss measure-
may be used for fiber identification. The LASER output is stabilized to ensure ments on MM or SM fiber optic links when used
accurate test results per current TIA/EIA requirements. with an optical power meter.

The OLS7 feature a triple wavelength LASER output from a single port and are easy to operate. Each The OLS4 features 850/1300 nm LED output
wavelength may be transmitted individually at CW or with user selectable modulated Tone. Also, each from a MM output port and 1310/1550 nm
wavelength may be transmitted with Wave ID. The OLS7 will also support transmitting pairs of wave- LASER output from a single-mode output port.
lengths in an alternating pattern and triple wavelengths in a sequential pattern. Associated with each Each wavelength may be transmitted individually at CW or with user se-
operating condition, the LED indicator will illuminate to identify the currently enabled operating mode lectable modulated Tone (SM output). When transmitting with Wave ID,
and emitted wavelength along with battery charge status and external power presence. the OLS4 supports transmitting pairs of wavelengths in an alternating
pattern. The designated LED indicator will illuminate to identify the cur-
rently enabled operating mode, emitted wavelength along with battery
charge status, & external power presence.

OLS7 Triple Wavelength Laser Sources $2398.00 OLS4 Laser Light Source with Wave ID $2205.00

Optical Power Meters

Optical Power Meter Features:
This portable optical power meter may be used to measure optical power (dBm) - Premises (Ge) and broadband (InGaAs) models.
in premises, telco, or broadband fiber optic networks. When used with an LED - Displays optical power (dBm).
or laser light source, the OPM1 can also measure the attenuation (insertion - Our simplest to use optical power meter.
loss) of MM or SM cables. Applications:
With only two controls – ON/OFF and wavelength – the OPM1 is our simplest to - The OPM 1-2C is calibrated at 850, 1300, 1310, and 1550 nm for
use optical power meter. Optical power in dBm and the calibration wavelength testing LAN, Ethernet, FDDI, Token Ring, and singlemode fiber systems
setting are displayed on an easy-to-read LCD display. The optical input port ac- such as Telco, WAN, and CATV.
cepts Noyes thread-on style connector adapter caps.
The OPM1 is fully N.I.S.T. traceable & runs on a standard 9-volt alkaline battery. OPM1-2C Optical Power Meter $425.00

OPM4 Optical Power Meter with Wave ID & Set Reference Features:
The OPM4 optical power meter may be used to measure optical power in Prem- - MM or SM applications.
ises, Telco, or Broadband fiber optic networks. When used with an LED or Laser - Wave ID - Automatic Wavelength Identification and Switching.
light source, the OPM4 also measures insertion loss of MM or SM cables. - Passive Optical Networks (PON) Testing.
The OPM4 offers Wave ID, automatic wavelength identification and switching, - 270 Hz, 330 Hz, 1 kHz, and 2 kHz Tone Detection.
when used with the OLS1-Dual, OLS2-Dual, or OLS4. Multiple test Tone detec- - Battery Gauge.
tion is provided for fiber identification. The OPM4 stores optical references for - N.I.S.T Traceable.
each calibrated wavelength. Shows measured power [dBm or μW] or insertion Wavelengths
loss [dB], calibrated wavelengths, tone signal [Hz], wavelength ID, and the bat- OPM4-1D ((((688855050000,,,, 171133381000000, 8,,, 11154330911) 000,,, 111555555000,), 11662255)) $515.00
tery charge status. OOOPPPMMM444---432DDD $$$554126500...000000

OPM5 Optical Power Meter with Wave ID, Set Reference, & Data Storage Features:
The OPM5 is a full-featured, handheld optical power meter designed for mea- - Rugged, handheld, lightweight.
suring optical power in Premises, Telco, or Broadband networks and performing - MM or SM applications.
insertion loss on MM or SM links. - Wave ID - Automatic Wavelength Identification and Switching.
The OPM5 features automatic wavelength identification and multiple test - Passive Optical Networks (PON) Testing.
Tone detection for fiber identification, and stores optical references for each - 270 Hz, 330 Hz, 1 kHz, and 2 kHz Tone Detection.
calibrated wavelength and up to 500 records per wavelength of power or inser- - Battery Gauge.
tion loss measurements. Using the supplied Windows® compatible software - N.I.S.T Traceable.
and USB connection, test records are transferred to a PC for analysis, printing,
and storage. Shows measured power [dBm or μW] or insertion loss, calibrated OPM5-2D Wavelengths $745.00
wavelengths, tone signal, wavelength ID, and estimated remaining battery life. OPM5-3D (((888555000,,, 91133800000, 1,, 11313301100, 1,, 411955055,001,) 5165205, 1) 625) $840.00
OPM5-4D $890.00

Adapter caps are required for operation of Optical Power Meters and are
ordered separately. See page 21.